Keep warm air warm. Cool air cool. 200mm insulated EPP ventilation ducting in a 1m length for MVHR heat recovery, air conditioning and suitable extract routes.
BlauTHERM
Help the air reach its destination at the temperature you want. This 200mm BlauTHERM duct is supplied in a 1m length, combining built-in thermal insulation with a tough, lightweight wall. Cut to fit with a sharp knife and connect matching push-fit fittings to build your MVHR, air-conditioning or extract route.

Keep conditioned air on course, then make the installation easier to handle, cut and connect.
Built-in insulation helps warmed air stay warm and cooled air stay cool between your MVHR or air-conditioning unit and the connected ductwork.
Insulation helps limit condensation risk along a correctly designed route. Suitable joints and sealing still matter, particularly in lofts and ceiling voids.
Measure, cut and fit the ducting and its insulation as one component.
Lightweight 1m lengths are easier to carry, lift and position in lofts, ceiling voids and plant areas.
Measure the gap and make a square cut with a sharp knife, including the short sections between fittings.
Push clean, matching parts fully home. Add BTG-500 EPP adhesive where extra joint strength and rigidity are required.
A robust expanded polypropylene duct body keeps weight down while retaining the insulation within the wall.
Plan corners, junctions and changes of diameter with matching bends, tees, reducers and beam adaptors. Add supports, silencers or BlauFast connections as required.
Planning a new build, self-build or renovation? Use BlauTHERM on suitable main duct routes between ventilation equipment and the connected system. It is a practical option for planned runs through lofts, ceiling voids and plant areas, with the diameter and layout chosen for your airflow and available space.

Help retain recovered warmth as air travels between your MVHR unit and the connected ductwork. Built-in insulation helps limit unwanted heat loss along the route, including sections passing through cooler spaces.
Carry cooled or warmed air towards the spaces it serves. Insulation helps limit unwanted heat gain or loss along the duct run, supporting the temperature your air-conditioning system is designed to deliver.
Build suitable extract routes for systems removing moisture-laden air from bathrooms, utility rooms and other wet areas. The ventilation system removes the moisture; duct insulation helps limit condensation risk along its route.
This product is the 200mm nominal diameter, supplied in a 1m straight length. Match it to the equipment connections and airflow specified for your installation. Need a different main duct size? The 125mm and 160mm versions are available as separate products below.
Separate product
1m straight length
Separate product
1m straight length
This product
1m straight length
BTID-200-1
Match the diameter to the required airflow and system design, and allow for the outside dimensions of the insulated duct when planning the available space.
Bring the lengths to the job, make the cuts you need and connect the route using matching fittings. The lightweight format is useful when lifting into position and working in the space available.

Measure the actual gap and cut square with a sharp knife. Adjust each straight section on site to suit the space between your fittings.
Plan a matching connector at each 1m duct joint. Keep the surfaces clean and push matching components fully together.
Use BTG-500 EPP adhesive where additional strength and rigidity are required, following its application and curing instructions.
Support the completed route, keep service items accessible, and measure and balance the system to its design airflow.
Use these product details alongside the route design, equipment requirements and current fitting instructions.
200mm is the nominal duct size used to select matching connections. Check the actual outside dimensions of the insulated duct and fittings when planning clearances; allow space for the insulation wall, joints and supports.
Check the outside dimensions of the exact fittings in your proposed route, alongside the duct body and support positions. Plan the assembly space before closing a ceiling void or boxing in the installation.
Yes. Plan the route using 1m straight lengths and any cut sections needed, with a matching connector at each 1m duct joint. Keep joints fully seated, support the completed run and maintain the insulation and sealing required by the design.
Measure the section and make a square cut with a sharp knife. Keep the joint surfaces clean before assembly, then push the matching components fully together. Check the fitting instructions for the required joint engagement.
Match adjoining duct lengths, couplers, bends, tees and other inline fittings to the specified 200mm route. Where a connection changes size, select a reducer with both diameters confirmed against the design.
Use it on suitable air-conditioning routes where the design specifies this diameter. The EPP insulation helps limit unwanted heat gain or loss, supporting the temperature the system is designed to deliver.
The range includes a 200mm-to-160mm reducer for a planned change of diameter. Check the equipment connection and the requirements of the full route before using the transition; choose the size to suit the design rather than the space alone.
A suitable ventilation system removes the moisture-laden air. Built-in duct insulation helps limit temperature changes and condensation risk along a correctly designed route. Pay attention to clean, fully seated joints, suitable support and any required vapour sealing.
| EAN Number | 5056194058490 |
|---|