Civic Floor Mounted Heat Recovery Ventilation Unit Decentralised School Classroom Ventilator - Built-in Controls - CIVIC-EC-LB-300

Order before 3pm for next-day UK delivery.
SKU
CIVIC-EC-LB-300
As low as £6,126.48 £5,105.40
 In stock
Model features
  • Air handling units with heat recovery
  • EC Motor
  • Low level noise
  • Single room air handling units with heat recovery
  • Work in mode extract and inflow
  • For commercial use

  • Floor standing decentralised heat recovery unit specifically designed for schools & civic areas.
  • Supply & extract airflow rate up to 83 l/s (300 m3/hour).
  • Fitted with efficient German Blauberg low energy EC motors.
  • Automatic summer bypass with CO2, humidity & temperature sensing.
  • Stylish wall mounted pre-wired speed control panel.

Use this Blauberg BIM object in your project:


OBJECTS INCLUDED:


  • CIVIC EC LB 300 S25
  • CIVIC EC LBE 300 S25
  • CIVIC EC LBE2 300 S25
HEAT RECOVERY VENTILATION IN THE CLASSROOM

Bad air quality

Insufficient ventilation in school classes, offices and conference halls results in bad air quality, i.e. high humidity level and CO2 concentration, low oxygen level. That provokes well known symptoms like dryness and irritation of ocular mucosa, lack of concentration, fatigue.

Bad air quality was proved to be the reason of work capacity reduction by 5-10% for adults. Children are affected even more. Thus bad air quality is one of the factors that impair success level of children at schools.

High humidity may lead to growth of mold and germs in a building, which means a risk of asthma and allergy attacks. Quality ventilation is one of the key factors to prevent such diseases. Window ventilation is a standard ventilation solution, but this method has a short effect and it also leads to heat losses.

Window ventilation is not able to solve a problem of high CO2 concentration, which several times exceeds a permissible level. Single-room ventilation, as opposed to window ventilation, provides a stable good air quality and saves heat energy.

Problem with heat losses

Reduction of heating costs is one of the main targets to be solved by reconstruction of schools and other public premises. Modern windows and doors are a part of this energy saving strategy due to their high density. At the same time airtight premises require efficient ventilation with heat recovery to maintain high air quality with low energy demand.

Limited mounting space for ventilation in reconstructed premises

Reconstruction of old buildings poses many engineering challenges requiring non-standard solutions. Arrangement of efficient ventilation system is one of such targets. However very often there is not enough space for mounting of air ducts and ventilation in renovated premise. In this case central ventilation is infeasible. Engineers select the single-room ventilation as it offers required ventilation solutions without the need to mount air ducts. It can be installed directly in the room to be ventilated.

FEATURES

The CIVIC EC LB units are designed for single-room ventilation of schools, offices and other public and commercial premises.Offer the ideal simple and efficient ventilation solutions for existing and renovated buildings and require no layout of air ducts.

Efficient supply and extract ventilation for separate premises.EC motors with low energy consumption.Low-noise operation.
Simple mounting.

DESIGN MOTORS

Made of high-quality polymer coated steel, internally lined with heat- and sound insulation of mineral wool or other materials.Built-in preheater and reheater modifications available for cold climate conditions.

High efficient electronically commutated motors with external motor and impeller with forward curved blades. Such motors are the most state-of-the-art energy saving solution.EC motors are featured with high performance and total speed controllable range. High efficiency reaching 90 % is the premium advantage of the electronically commutated motors.

AIR FILTRATION

Supply and extract air is purified by a set of panel filters. Filtering class depends on the unit model.Panel G4 filter is used for extract air filtration.

BYPASS CONTROL AND AUTOMATION

The units are equipped with a bypass. The bypass damper opens for free cooling ventilation mode in summer.

The CIVIC EC LB 300 S25 units are equipped with an integrated automation system.
The S25 controller allows integrating the unit into the BMS (Building Management System).
The unit can be controlled by the Blauberg AHU mobile application via Wi-Fi.

Download
the Blauberg AHU
app for Android

Download
the Blauberg AHU
app for iOS
 

The CIVIC EC LB 300 S25 units are equipped with an integrated automation system and the S25 wall mounted sensor control panel with LED-indication.

AIR DAMPERS

The automatic supply and extract air dampers are used to prevent uncontrollable air draughts during the unit standstill.

HEATERS

PREHEATING

CIVIC EC LBE and CIVIC EC LBE2 units are equipped with an electric preheater which protects the heat exchanger from freezing.

REHEATING

CIVIC EC LBE2 units feature an electric reheater to raise the supply air temperature.

HEAT EXCHANGER AUTOMATION FUNCTIONS

The CIVIC EC LB unit has a counter-flow heat exchanger made of polystyrene.

• In cold season the heat energy of the extract air flow is absorbed by intake air flow, thus decreasing the heat losses caused by ventilation. Condensate generated during heat recovery is collected in a drain pan and removed to the sewage system.

• In warm season the heat of the outdoor air is absorbed by extract air flow. This way the supply air temperature decreases and heat recovery reduces operation loads for the air conditioner.

The CIVIC EC LB... -E unit is equipped with a counter-flow heat exchanger made of enthalpy membrane.

• In cold season the heat and moisture of the extract air are absorbed by supply air through the enthalpy membrane. thus decreasing the heat losses caused by ventilation.

• In warm season the heat and humidity of the outdoor air is absorbed by extract air flow through the enthalpy membrane. This way the supply air temperature and humidity decreases and heat recovery reduces operation loads for the air conditioner.


Functions

CIVIC EC LB 300 S21

CIVIC EC LB 300 S25
Unit control via Wi-Fi using the mobile application + -
Unit control via remote control panel
S22 control panel (option)
-
Unit control via remote wireless control panel
S22 Wi-Fi control panel (option)
-
Unit control via a wired remote LCD control panel
S25 control panel (option)

S25 control panel
BMS (Building Management System)  RS-485 -
Wi-Fi -
Ethernet -
MODBUS (RTU, TCP) -
Blauberg Cloud Server service + -
Speed switch + +
Filter replacement indication by filter timer by filter timer
Alarm indication full alarm description in the mobile application LED indication about alarms
Week scheduled operation + -
Bypass automatic -
manual manual
Timer + -
Boost mode + -
Fireplace mode + -
Freeze protection using cyclical stops of the supply fan using cyclical stops of the supply fan
using preheating (option) -
Reheater connection option -
Cooler connection option -
Minimum supply air temperature control + -
Humidity control option option
CO₂ control option option
VOC control option -
PM2.5 control option -
Fire alarm sensor connection option option
Option: the functionality is available when purchasing the appropriate accessory (see the "Accessories" section)
FUNCTIONING

Cold outside air flows through the filters and heat exchanger and is moved to the room with a supply centrifugal fan.

Warm polluted air from the premise flows through the filter and the heat exchanger and is exhausted outside with an extract centrifugal fan.

Technical details
ManufacturerCivic
Impeller TypeCentrifugal
Motor TypeEC
Electrical Supply1 Phase 220/250 50/60Hz
Energy RatingERP 2018
Tax ClassTaxable Goods

You might also like to use this Blauberg BIM objects in your project:


Dimensions
  CIVIC-EC-LB-300 S25
Outer ventilation hood made of brushed stainless steel AH Civic 300 LB chrome
Outer ventilation hood made of white coated steel AH Civic 300 LB white
G4 filter FP 308x238x22 G4 PPI
G4 filter FP 265x213x48 G4 
F8 filter FP 384x273x60 F8 
 F8 carbon filter FP 533x135x48 F8 C
H11 HEPA filter FP 533x135x60 H11
Control panel S22
Wi-Fi control panel S22 Wi-Fi
LCD Control panel S25
VOC sensor DPWQ30600
CO₂ sensor DPWQ40200
Humidity sensor DPWС11200
CO₂ sensor with indication CD-1
CO₂ sensor CD-2
Internal humidity sensor  FS2
Humidity sensor HR-S
Syphon kit  SFK 20x32
Drain pump CP-2