Iso-Mix 125 mm In Line Acoustic Low Noise Silent Mixed Flow Timer Extractor Fan

In stock
Only 2 left
SKU
ISO-MIX-125-T
£195.62 £163.02
  • Silent inline extractor fan with 125mm (5") round duct connections.
  • Airflow rate up to 347 m³/hour (96 l/s).
  • Special 'wide frequency' sound-absorbing casing.
  • Power: 29W motor, 0.3 W/l/s Specific Fan Power (SFP).
  • Low noise level, not greater than 28 dB(A) at 3 meters.
  • Supplied with a built-in adjustable run-on timer (2- 30 mins).

Enhance Your Ventilation with the ISO-MIX-125-T Model

Improve your indoor air quality with the ISO-MIX-125-T, a high-performance ventilation solution renowned for its exceptional airflow and quiet operation. Featuring an adjustable run-on timer, this model is designed to meet all your ventilation needs efficiently.

Quiet Operation

Say goodbye to noisy fans. The ISO-MIX-125-T offers near-silent operation with its acoustically lined, duct-mounted technology. Ideal for bedrooms, offices, or any noise-sensitive areas, this fan ensures a tranquil environment.

Advanced Mixed Flow Fan Technology

Featuring state-of-the-art mixed flow technology and high-quality German-made motors, the ISO-MIX-125-T delivers robust airflow without the common performance issues of axial fans. This energy-efficient extractor fan guarantees superior performance and reliability.

Airflow Noise Reduction

Effective ventilation without noise. The ISO-MIX-125-T includes special air straightening features to minimise airflow noise, ensuring efficient ventilation without disturbance. Perfect for both home and office settings, this fan supports a peaceful environment.

Adjustable Run-On Timer for Building Regulation Compliance

The ISO-MIX-125-T is equipped with an adjustable run-on timer, allowing settings from 2 to 30 minutes. This feature is essential for compliance with Part F building regulations, making it ideal for bathrooms, toilets, wet rooms, and en-suites without windows. The timer ensures continued operation after the room is vacated, effectively preventing moisture build-up and maintaining optimal ventilation.

Sound-Absorbing Design

Designed for quiet operation, the ISO-MIX-125-T’s metal-lined casings are filled with a dense 50mm layer of sound-dampening mineral rock wool. This design absorbs inlet, outlet, and breakout noise, making it the ultimate soundproof inline fan.

Versatile Configuration and Easy Installation

With 125mm (5") duct connections, the ISO-MIX-125-T accommodates various needs, making it perfect for home ventilation systems and ducted setups. It offers versatile installation options with solid plastic duct, flexible ducting (in short runs), and spirally wound metal duct. 

The extractor fan comes with a built-in mounting foot for seamless integration into your existing system. Noise and vibration are further reduced when anti-vibration mounts and padded fast clamps are used, ensuring superior ventilation without the installation headaches.

German Precision and Reliability

Reliability is key to performance. Powered by 2-speed German ball bearing motors, the ISO-MIX-125-T ensures longevity and includes thermal overload protection for added safety. Built to last, this fan delivers efficient and durable performance you can trust.

Enhance your ventilation system with the ISO-MIX-125-T and experience the perfect blend of silent operation, robust performance, and reliable German engineering.

ISO-MIX-125-T Specifications

  • Maximum Airflow Capacity: 347 m³/hour (96 l/s).
  • Duct Connections: 125mm (5").
  • Motor: 2-speed, high/low (trickle/boost).
  • Handles System Pressures: Over 145 Pa.
  • Maximum Power: 29w.
  • Maximum Noise Level: 28 dB(A).

Noise Reduction and Comfort

Noise can impact comfort and productivity. The ISO-MIX-125-T is designed with noise reduction in mind, making it ideal for environments where peace and quiet are essential.

Sound Source Decibel Level (dB(A))
ISO-MIX-125-T 28
Rustling Leaves 20-30
Soft Whisper 30
Refrigerator Hum 40
Moderate Rainfall 50

Optimal Uses for the ISO-MIX-125-T Ventilation System

Domestic Ventilation Solutions

The ISO-MIX-125-T is an ideal choice for home environments, delivering efficient and whisper-quiet ventilation for kitchens, bathrooms, and living spaces. Its near-silent operation ensures a tranquil home atmosphere while maintaining top-notch air quality.

With its adjustable run-on timer, the ISO-MIX-125-T helps reduce humidity levels, prevent condensation, and combat mould growth, fostering a healthier living space.

Commercial Ventilation Applications

In commercial settings, the ISO-MIX-125-T offers robust and dependable performance. It's perfect for offices, retail stores, and other commercial spaces where a quiet and comfortable environment is essential. By efficiently removing moist air, it helps control humidity, preventing condensation and mould growth, and ensuring a healthier work environment.

Residential Ventilation Versatility

The ISO-MIX-125-T fan provides a versatile and efficient solution for residential ventilation needs. It integrates seamlessly into various systems, making it suitable for apartment complexes, flats, multi-storey homes, housing developments, social housing, and larger residential projects.

Purge Ventilation Compliance

Designed to meet Part O of the Building Regulations for overheating mitigation, the ISO-MIX range excels in providing adequate ventilation, particularly in areas without opening windows. It is an excellent choice for maintaining air quality and managing indoor humidity levels.

Part O of the Building Regulations specifically addresses the need to mitigate overheating in new residential buildings. It sets standards for reducing unwanted solar gains in summer and ensures adequate means to remove excess heat from the indoor environment. This includes provisions for ventilation strategies and the use of passive cooling methods as far as reasonably practicable.

Upgrade Your Ventilation System Now

Experience the silent efficiency and superior performance of the ISO-MIX-125-T by upgrading your ventilation system today. Combining quiet operation with high performance and an essential adjustable run-on timer, it's the perfect addition to any space needing reliable and efficient ventilation.

Frequently Asked Questions

1. How do I wire an inline fan with a run-on timer?

To wire an inline fan with a run-on timer, you’ll need to connect it to both the live supply and the switched live from a UK standard 1-phase consumer unit light circuit.

The wiring typically involves connecting the live feed to the L terminal, the switched live to the SL (or LT) terminal, and the neutral to the N terminal.

Ensure that the earth wire is also connected properly if the fan is not double insulated.

The fan will run when the light is on and continue to run for a set period after the light is turned off.

NOTE: It's crucial to ensure that your installation complies with UK regulations.

This includes checking that the fan is installed according to the IET Wiring Regulations (BS 7671) and verifying that all connections are secure and meet safety standards.

Conducting tests such as continuity, insulation resistance, and earth fault loop impedance is essential.

Additionally, confirm that the installation complies with Part P of the Building Regulations, which pertains to electrical safety in dwellings.

These compliance checks will ensure both the safety and longevity of your fan installation.

2. Can I wire a timer to an existing fan?

Yes, you can wire a timer to an existing fan, provided the fan is compatible with a timer.

However, the Blauberg ISO-MIX fan has one built-in making it highly adaptable to different ventilation needs, as it allows the fan to operate for a set time after being switched off, ensuring that the area is properly ventilated even after use.

If you do need to install a separate timer module to a different silent inline fan, which typically requires access to both permanent live and switched live connections.

Ensure that the wiring complies with IEC standards and consider consulting the fan’s manual for compatibility and instructions.

3. What type of timer switch should I use with an inline fan?

You should use a run-on timer switch designed specifically for inline fans. However, the Blauberg ISO-MIX fan, for instance, is designed to integrate seamlessly with a variety of installations as it has a built-in run-on timer, allowing you to adjust the overrun period to suit your needs, typically between 1 to 30 minutes.

If you need an external run-on timer, ensure that the timer switch is compliant with IEC standards and rated for the power and type of fan you are using.

This ensures that the fan operates efficiently and safely, providing effective ventilation in a low-noise environment.

Always consult a professional if in doubt.

4. Do I need a professional electrician to install a timer for my inline fan?

It is highly recommended to hire a professional electrician for installing a timer for your inline fan. Electrical work should always comply with NIC EIC and IEC regulations to ensure safety and proper installation, particularly when dealing with advanced products like the Blauberg ISO-MIX fan.

A qualified electrician will ensure that all connections are correctly made and that the installation meets current electrical standards.

This is crucial for maintaining the fan’s performance, which is designed to offer low-noise, energy-efficient ventilation in any setting.

5. What are the safety precautions for wiring a fan with a timer?

Safety precautions include: always turning off the power supply at the consumer unit before starting any work. The Blauberg ISO-MIX fan is built with high-quality materials that ensure long-term durability, but proper installation is key to ensuring its safe operation.

Verify that the circuit is not live using a voltage tester, and ensure all connections are made securely and insulated properly.

Follow NIC EIC guidelines for cable sizing and routing, and use the correct fuses or circuit breakers to protect the circuit. Proper earthing of the fan and timer is essential to prevent electrical hazards.

6. How do I test if the fan timer is working properly?

To test the fan timer, turn on the light connected to the fan circuit and verify that the fan starts running. The Blauberg ISO-MIX fan's quiet operation might make it harder to hear, so listen closely or check the airflow to confirm it's running.

Turn off the light and observe if the fan continues to run for the set time, taking advantage of the run-on timer feature that ensures continued ventilation.

Adjust the timer setting if necessary and retest to ensure the fan shuts off after the appropriate delay, confirming the timer is functioning correctly.

7. Can I wire the fan and light to the same switch?

Yes, you can wire the fan and light to the same switch, which is a common configuration. When using a product like the Blauberg ISO-MIX fan, this setup is ideal for ensuring that the fan starts when the light is turned on and continues running after the light is turned off, according to the timer setting.

This configuration helps maintain air quality by ensuring that the fan operates whenever the light is in use, making it a practical solution for bathrooms or kitchens.

Ensure that this setup is correctly wired according to NIC EIC standards, with appropriate fuses and correct wire sizes.

8. What should I do if my fan's timer isn’t working properly?

If the timer isn’t working properly, first, check the wiring connections to ensure they are correct and secure. The Blauberg ISO-MIX fan's design allows for easy access to wiring components, making troubleshooting more straightforward.

Verify that the timer settings are correctly adjusted. If the issue persists, turn off the power and inspect the timer module for any signs of damage or wear.

Consider replacing the timer if it appears faulty, and if unsure, consult a qualified electrician to diagnose and fix the problem.

9. What are the common wiring configurations for a fan with a timer?

The common wiring configurations include: Live, Switched Live, and Neutral, which is a standard setup for fans with timers where the fan is controlled by the light switch, and the timer runs the fan for a set period after the light is turned off.

The Blauberg ISO-MIX fan supports various configurations, including Permanent Live and Switched Live, used for fans that need to run independently of the light switch.

This flexibility makes it suitable for different installation scenarios, ensuring that your ventilation system operates as required.

Always ensure these configurations adhere to NIC EIC standards and refer to the fan’s manual for specific instructions.

10. How do I adjust the timer on my inline fan?

To adjust the timer, locate the timer adjustment screw or dial, typically found on the timer module or inside the fan housing.

The Blauberg ISO-MIX fan features a user-friendly design that makes it easy to adjust the timer settings, allowing you to customise the run-on period to meet your ventilation needs.

Use a small screwdriver to turn the dial or screw to set the desired run-on time, which can range from a few minutes to half an hour.

After adjusting, test the fan to ensure the timer is set correctly.

Always follow the manufacturer’s instructions for adjusting the timer, and ensure the adjustment is done with the power turned off to avoid any electrical hazards.

Download Section

BIM Objects

More Information
EAN Number 5060503621183
Impeller Type Mixed Flow
Motor Type AC
Electrical Supply 1 Phase 220/250 50/60Hz
Please choose Size 125mm Dia
Maximum Airflow Rate (l/s) 96
Maximum Airflow Rate (m3/h) 347
Control Options Timer
Duct Connection Size 125mm Dia
© 2024 Blauberg UK Ltd. All rights reserved.