Blauberg RENEO-180 MVHR Heat Recovery Ventilation Unit

This product will be in stock soon.
SKU
RENEO-180-CON
  • Up to 50 l/s airflow in a low-profile format for planned whole-home ventilation.
  • Up to 91% heat recovery to retain useful warmth from outgoing air.
  • Built-in humidity sensing with F7 supply filtration and automatic summer bypass.
  • Two 272 mm-high ceiling- or wall-mounted models for app control or Modbus RTU/TCP home integration.
  • 5-year warranty UK range cover. Warranty terms apply.
A calm contemporary living room with a discreet ceiling ventilation grille, natural daylight and pale oak finishes

A Day with aRENEOMVHR System

RENEO runs continuously, filtering incoming air, recovering useful warmth and carrying away stale air, excess moisture and everyday odours.

WEEKLY SCHEDULE
Fresh air for the morning.

Scheduled airflow keeps the morning fresh without opening windows.

AIR-QUALITY RESPONSE
Humidity rises. Airflow responds.

After showering, airflow rises to clear moisture, then settles back.

TIMED BOOST
Cooking air cleared.

Timed boost clears cooking air, then automatically returns to normal.

EVERYDAY AIRFLOW
Quiet comfort through the night.

Fresh air keeps moving while useful warmth is recovered.

A host of features,
across two units.

RENEO-180

App control

Simple everyday control.

Wi-Fi app control, scheduling, timed boost, system alerts and operating-data logging.

Choose this ifYou want straightforward control from your phone.
RENEO-180-S

Home integration

Ready to integrate.

RENEO S (S21) adds Modbus RTU/TCP connectivity and compatible external-heater control for wider home and building systems.

Choose this ifYour ventilation must connect to a wider control system.
Every model includes Filtered fresh air Recovered warmth Humidity response Summer bypass App control
Optional S25 LCD touchscreen control panel for the RENEO-180 range

Add the S25 LCD display.

Add an optional wall-mounted touchscreen for clear, convenient local control of both RENEO-180 models.

Illustrative contemporary British living space with oak finishes, soft furnishings and a garden viewBlauberg RENEO-180 MVHR heat recovery ventilation unit

Fresh air.
Warmer home.
Better living.

Continuous fresh air and recovered warmth,
working quietly throughout the home.

50 l/sMaximum airflowFresh air throughout
91%Heat recoveryMore warmth retained
F7Supply filtrationCleaner incoming air
5 yearsUK warrantyPeace of mind

Low-profile ventilation, designed around the space.

RENEO-180 unit moving air through its four duct connections
50l/sMaximum airflow

Planned whole-home airflow in a low-profile format.
Works with planned 160 mm duct systems; select against calculated system resistance.

Counterflow heat-recovery core with warm and cool air paths
91%Heat recovery, up to

More warmth retained.
Transfers useful warmth from extract air to the incoming supply.

F7 supply filter withdrawing from a RENEO unit
F7Supply filtration

Cleaner incoming air.
Reduces pollen and fine airborne particles before air reaches living spaces.

Home energy efficiency rating scale
A+SEC energy class

Efficient by design.
Designed for efficient year-round ventilation.

RENEO automatic summer-bypass airflow cutaway
AutoSummer bypass

Comfort across the seasons.
Stops recovering heat when cooler outdoor air can help.

RENEO smartphone app and touchscreen controller
Wi-FiIntelligent control

Comfort that responds.
App control and humidity response keep adjustment simple.

Choose your RENEO.

Choose straightforward app control or wider home and building connectivity.

RENEO-180AppEveryday Wi-Fi app control and operating-data logging.
RENEO-180-SHomeAdds Modbus TCP and compatible external-heater control.
Compare every featureView the complete RENEO-180 and RENEO-180-S comparison
Feature
RENEO-180Home app control
RENEO-180-SHome app + building connectivity
Home & building connectivityControl by phone or connect to wider building controls
Home app control
Home app + building connectivity
50 l/s maximum airflowPlanned whole-home ventilation in a low-profile format
✓
✓
Ceiling or wall mounting272 mm-high casing for a planned service space
✓
✓
A+ SEC energy classEfficient year-round operation
✓
✓
160 mm duct connectionsCoordinated for the low-profile RENEO-180 casing
✓
✓
Up to 91% heat recoveryMore warmth retained
✓
✓
F7 supply filtrationCleaner incoming air
✓
✓
G4 extract filtrationProtects the unit on the extract-air side
✓
✓
Automatic summer bypassComfort across the seasons
✓
✓
Built-in humidity sensingResponds when moisture rises
✓
✓
Wi-Fi app controlControl from phone or tablet
✓
✓
S25 LCD wall controlOptional touch-screen control panel
Optional
Optional
CD-3 CO₂ sensorOptional demand-led air-quality control
Optional
Optional
Control platformThe controller determines integration and logging features
RENEO (S71)
RENEO S (S21)
BMS connectivityIntegration with wider building controls
Modbus RTU
Modbus RTU / TCP
External heater controlControls a compatible external heater when specified
—
✓
Operating data loggingRecorded operating information
✓
—
Built-in preheaterClarifies the cold-weather equipment included in the unit
Not included
Not included
Maximum power inputPublished electrical maximum
53 W
53 W
Maximum currentPublished electrical maximum
0.49 A
0.49 A
Acoustic data at 70% duty29 dB(A) LpA at 3 m / 49 dB(A) casing LwA
✓
✓

Professional MVHR design.
Planned around your home.

Discussing the requirements for an MVHR project 01Discovery

Start with the home.

Discuss the plans, priorities and ventilation requirements.

Detailed MVHR system design 02Design

Calculate every room.

Calculate room airflow, select the unit and plan practical duct routes.

MVHR plans being presented 03Presentation

See the system clearly.

Review 2D, 3D or DWG proposals before installation begins.

MVHR installation support 04Installation

Build with confidence.

Technical guidance helps keep the installation faithful to the design.

Completed and commissioned MVHR system 05Completion

Finish as designed.

Fine-tuning, sensor setup and as-built options complete the handover.

Residential MVHR floor plan with calculated ventilation routes

Professional MVHR design.Guaranteed to meet Building Regulations.

Bring your plans. Leave with a system that works. A focused 15-minute conversation about your plans and the right design route. Book a free 15-minute consultation
Dimensions & installationShared RENEO-180 dimensions, dimensional drawing and model weights
RENEO-180 dimensional drawing

Shared dimensions across both models

Ø D160 mm
H272 mm
L930 mm
L1617 mm
W640 mm
W1300 mm

Model weights

RENEO-18012 kg
RENEO-180-S12 kg

Frequently asked questions

How do the two Blauberg RENEO-180 MVHR models compare?

Both models provide up to 50 l/s airflow, up to 91% catalogue heat recovery, F7 supply and G4 extract filtration, built-in humidity sensing, Wi-Fi app control and automatic summer bypass. RENEO-180 uses the RENEO (S71) platform with Modbus RTU and operating-data logging, while RENEO-180-S uses RENEO S (S21) for Modbus RTU/TCP and compatible external-heater control.

Why is the RENEO-180 described as a low-profile MVHR unit?

The casing is only 272 mm high, helping the unit fit into a carefully planned ceiling void or a compact wall-mounted service area. Allowance is still required for the 930 x 640 mm casing footprint, 160 mm duct connections, filters, cover, condensate drain and maintenance access.

Can RENEO-180 be ceiling or wall mounted, and can it be floor mounted?

Both RENEO-180 models support ceiling or wall mounting. Floor mounting is not specified for this low-profile casing. For wall installation, follow the orientation and condensate-drain fall or tilt required by the current installation manual.

What does the 50 l/s maximum airflow mean for system design?

The 50 l/s figure is the catalogue maximum, not the guaranteed airflow at every system pressure. Final selection must use the room-by-room ventilation duty and the resistance of the complete 160 mm duct system at the intended commissioned operating point.

How much heat can the RENEO-180 family recover?

Catalogue heat recovery is up to 91%. Published performance results vary by duty and test method, so confirm that any quoted result applies to the exact model and operating point. Real performance also depends on airflow, temperatures, duct resistance and commissioning.

Which replacement filters fit the RENEO-180 range?

UK RENEO-180 models use an F7 supply filter and a G4 extract filter. The corresponding replacement references are FP-205-200-48-F7 and FP-205-200-48-G4; confirm the current grade and part reference before ordering.

Which controller platform is fitted to RENEO-180 and RENEO-180-S?

RENEO-180 uses the RENEO (S71) controller for Wi-Fi app control, Modbus RTU and operating-data logging. RENEO-180-S uses the RENEO S (S21) controller, adding Modbus TCP and compatible external-heater control but not the RENEO (S71) model's operating-data logging feature.

Does either RENEO-180 model include a built-in preheater?

No. Neither RENEO-180 nor RENEO-180-S includes a built-in preheater. RENEO-180-S can control a compatible external heater through its RENEO S (S21) platform when one is correctly specified as part of the project.

What service space and drainage allowance does RENEO-180 need?

Retain clear access to the cover, filters, heat exchanger, electrical connections and condensate drain. The drain must keep the fall, trap and frost protection required by the installation manual, and the unit position must allow future cleaning and component removal.

What should be checked before specifying a RENEO-180 MVHR system?

Confirm room-by-room supply and extract rates, total airflow, duct resistance, acoustic treatment, ceiling or wall position, condensate routing, controls, electrical requirements and commissioning access. Correct installation and maintenance also support the five-year UK warranty, subject to its current terms.

© 2025 Blauberg UK Ltd. All rights reserved.