
A Day with aRENEOMVHR System
RENEO runs continuously, filtering incoming air, recovering useful warmth and carrying away stale air, excess moisture and everyday odours.
Fresh air for the morning.
Scheduled airflow keeps the morning fresh without opening windows.
Humidity rises. Airflow responds.
After showering, airflow rises to clear moisture, then settles back.
Cooking air cleared.
Timed boost clears cooking air, then automatically returns to normal.
Quiet comfort through the night.
Fresh air keeps moving while useful warmth is recovered.
A host of features,
across three units.
App control
Simple everyday control.
Wi-Fi app control, scheduling, timed boost, system alerts and operating-data logging.
Home integration
Ready to integrate.
RENEO S (S21) adds Modbus RTU/TCP connectivity and compatible external-heater control for wider home and building systems.
Integration + preheat
Connected control with winter protection.
RENEO SE (S21 and preheater) combines home integration and external-heater control with an integrated 1,400 W preheater for specified cold-weather protection.

Add the S25 LCD display.
Add an optional wall-mounted touchscreen for clear, convenient local control of all three RENEO-270 models.


Fresh air.
Warmer home.
Better living.
Continuous fresh air and recovered warmth,
working quietly throughout the home.
Compact upright ventilation, thoughtfully sized.

Whole-home airflow in a compact upright format.
Works with planned 125 mm duct systems; select against calculated system resistance.

More warmth retained.
Transfers useful warmth from extract air to the incoming supply.

Cleaner incoming air.
Reduces pollen and fine airborne particles before air reaches living spaces.

Efficient by design.
Designed for efficient year-round ventilation.

Comfort across the seasons.
Stops recovering heat when cooler outdoor air can help.

Comfort that responds.
App control and humidity response keep adjustment simple.
Choose your RENEO.
Choose the control, connectivity and preheating your project needs.
Compare every featureView the complete RENEO-270, RENEO-270-S and RENEO-270-SE comparison
Professional MVHR design.
Planned around your home.
01Discovery
Start with the home.
Discuss the plans, priorities and ventilation requirements.
02Design
Calculate every room.
Calculate room airflow, select the unit and plan practical duct routes.
03Presentation
See the system clearly.
Review 2D, 3D or DWG proposals before installation begins.
04Installation
Build with confidence.
Technical guidance helps keep the installation faithful to the design.
05Completion
Finish as designed.
Fine-tuning, sensor setup and as-built options complete the handover.
Dimensions & installationShared RENEO-270 dimensions, dimensional drawing and model weights

Shared dimensions across all three models
Model weights
Frequently asked questions
How do the three Blauberg RENEO-270 MVHR models compare?
All three models provide up to 92 l/s airflow, up to 89% catalogue heat recovery, F7 supply and G4 extract filtration, built-in humidity sensing, Wi-Fi app control and automatic summer bypass. RENEO-270 uses the RENEO (S71) platform with operating-data logging, RENEO-270-S uses RENEO S (S21) for Modbus RTU/TCP and external-heater control, and RENEO-270-SE adds an integrated 1,400 W preheater.
Where is the compact upright RENEO-270 range designed to be installed?
Its 598 mm-wide upright casing suits a planned cupboard, utility room or plant area. All three UK models can be wall or floor mounted, with clear access retained for the cover, filters, heat exchanger, electrical connections and condensate drain.
What does the RENEO-270 maximum airflow of 92 l/s mean for system design?
The 92 l/s figure is the catalogue maximum, not the guaranteed airflow at every system pressure. Final selection must use the room-by-room ventilation duty and the resistance of the complete 125 mm duct system at the intended commissioned operating point.
How much heat can the RENEO-270 family recover?
Catalogue heat recovery is up to 89%. Published independent test results vary by duty and test method, while real performance also depends on airflow, indoor and outdoor temperatures, duct resistance, commissioning and operating conditions.
Which filters fit the Blauberg RENEO-270 range?
UK RENEO-270 models use an F7 supply filter and a G4 extract filter. The corresponding replacement references are FP-356-100-48-F7 and FP-356-100-48-G4; confirm the current grade and part reference before ordering.
Which controller platform is fitted to each RENEO-270 model?
The standard RENEO-270 uses the RENEO (S71) controller. RENEO-270-S and RENEO-270-SE use the RENEO S (S21) controller, which adds Modbus TCP and compatible external-heater control but does not include the RENEO (S71) model's operating-data logging feature.
Which RENEO-270 variants support Modbus TCP and external-heater control?
RENEO-270-S and RENEO-270-SE provide Modbus RTU/TCP and compatible external-heater control through the RENEO S (S21) platform. The RENEO (S71)-controlled RENEO-270 provides Modbus RTU and operating-data logging instead.
Which RENEO-270 model includes the 1,400 W preheater?
Only RENEO-270-SE has the integrated 1,400 W electric preheater. It supports the specified cold-weather frost-protection strategy; it is not a whole-house heating system and does not replace the property's space heating.
What space and drainage allowance does a floor-mounted RENEO-270 need?
Published dimensions are 900 mm high, 452 mm long and 598 mm wide, with an H1 dimension of 958 mm. For floor mounting, provide supports with at least 150 mm beneath the unit for trapped condensate drainage and retain the service clearances required by the model manual.
What should be checked before specifying a RENEO-270 MVHR system?
Confirm room-by-room supply and extract rates, total airflow, duct resistance, acoustic treatment, unit position, condensate routing, controls, electrical requirements and commissioning access. Correct installation and maintenance also support the five-year UK warranty, subject to its current terms.

