PASSIV+240H

Specific Fan Power & Thermal Efficiency Results

Configuration Specific Fan Power (W/l/s) 2009 Specific Fan Power (W/l/s) 2012 Heat Exchange Efficiency (%) 2009 Heat Exchange Efficiency (%) 2012
Kitchen + 1 Wet Room 0.38 0.41 93 93
Kitchen + 2 Wet Rooms 0.37 0.43 93 92
Kitchen + 3 Wet Rooms 0.40 0.51 92 91
Kitchen + 4 Wet Rooms 0.46 0.64 92 91
Kitchen + 5 Wet Rooms 0.53 0.78 91 91
Kitchen + 6 Wet Rooms 0.62 0.98 91 89
Kitchen + 7 Wet Rooms 0.75 1.20 90 89