Small footprint.
Fresh thinking.
Every day.
Fresh air. Recovered warmth. Everyday comfort.
Discover whole-home ventilation designed to work beautifully behind the scenes.


Small in size.
Considered
in every detail.
You put care into every part of a home.
The air inside deserves the same.
RENEO-120 supplies filtered fresh air to living spaces and extracts stale air from wet rooms, recovering useful warmth along the way. Its 242 mm high ceiling-mounted casing keeps useful wall and floor space free.
Select against calculated airflow and system resistance. Maximum airflow is not available at every pressure; final suitability depends on the complete system design.
Comfort comes
as standard.
Useful warmth retained. Incoming air filtered. Moisture considered. The fundamentals are already part of the specification.
Keep more
of the warmth.
A counterflow heat exchanger recovers energy from outgoing air, helping reduce the heat lost through ventilation.
F7Fresh air.
Filtered first.
F7 supply filtration is standard, filtering incoming airborne particles before air reaches living spaces.
Humidity Sensor
Built-in.
Humidity sensing helps manage moisture from bathing, cooking and day-to-day life, without specifying an add-on humidity sensor.
1. Up to 94% catalogue heat recovery. Actual performance depends on operating conditions. Independent test results are shown separately below.
Your home.
Your rhythm.
Ventilation that fits the way you live.
Use the Blauberg Home app to plan ventilation around your routine, respond when more airflow is needed and keep track of filter maintenance.
- Set a weekly schedule. Match operation to the household routine.
- Boost when needed. Access everyday controls from your phone.
- Stay informed. Filter reminders and alarm indication help you keep on top of maintenance.
- Keep the specification clear. RENEO-120 is the RENEO (S71) model, without summer bypass or external-heater control.

S25 LCD wall panel

Better air.
A shared ambition.
Different priorities. One carefully considered system. Choose your role to see what RENEO-120 brings to your project.
Your selected model.
F7 supply filtration, built-in humidity sensing and Wi-Fi app control are included. Here is the exact control specification for RENEO-120.
RENEO-120
RENEO (S71) connected control with operating data logging. A clear starting point for everyday whole-home ventilation.
- Controller
- RENEO (S71)
- Preheater
- Not included
- Modbus
- RTU
- Data logging
- Yes
- External-heater control
- No
- Max. total power
- 59 W
- Max. total current
- 0.5 A

Performance measured.
Confidence earned.
Independent testing puts numbers behind the promise. RENEO-120 reference results measure fan energy use and heat recovery. Use the data at the required duty and keep its scope clear.
UK performance summary
BL-F97 calculation summary
| Test point | Airflow [l/s] | Specific fan power [W/(l/s)] |
|---|---|---|
| 1 | 21.0 | 0.65 |
| 2 | 29.0 | 0.78 |
| 3 | 37.0 | 1.16 |
Thermal efficiency: 83%. Separate summary figure; its duty point is not identified in the supplied extract.
BL-F97 UK calculation summary. SAP method and PCDB status are not stated. Catalogue heat recovery and the thermal summary are separate data.
Find your design duty.
Open full-size curve
Ready for the drawing board.
Dimensions and specifications for RENEO-120. Control and total electrical ratings appear in your selected-model section above.

- H
- 242 mm
- L
- 530 mm
- L1
- 630 mm
- W
- 520 mm
- W1
- 600 mm
- Weight
- 8 kg
Mounting & maintenance access
Ceiling mounting only. Keep access below clear for cover and filter removal. Provide trapped condensate drainage and access to controls and electrical connections.
- Maximum airflow
- 43 l/s
- Catalogue heat recovery
- Up to 94%
- Duct connections
- 100 / 125 mm
- Mounting
- Ceiling only
- Supply filter
- F7 standard
- Extract filter
- G4
- Humidity Sensor Built-in
- Yes
- Summer bypass
- No
- Electrical supply
- 230 V, 50/60 Hz
- Maximum fan power
- 59 W
- SEC class
- A
- UK arrangement
- Left-hand
- Casing / insulation
- EPP / 25 mm
- Heat exchanger
- Counterflow polystyrene
- Indoor ambient
- +1 to +40°C; max. 60% RH, non-condensing
- Transported air
- −23 to +40°C
Acoustic performance · at 70% airflow
LpA
LwA
LpA uses spherical free-field conditions. Installed room noise depends on operating duty, location and attenuation.
The right finishing touches.
Plan controls, attenuation and drainage alongside the unit. Keep the correct replacement filters on the maintenance schedule.

F7 supply filter
FP-176-150-22-F7Replacement for the standard supply filter.

G4 extract filter
FP-176-150-22-G4Replacement extract filter.

LCD wall control
S25Optional wired touch-screen panel.

Wall control
S22Optional wired panel.

CO₂ sensor
CD-3Optional demand-control sensor.

Duct silencer
SD-125-600600 mm long; reduces duct noise.

Condensate trap
SFK 20x32Syphon kit for condensate drainage.
Accessory images are illustrative. Confirm the exact model when ordering.
The lifestyle image is an illustrative AI-created visual, not a completed project photograph. Original product and accessory images are illustrative. Specifications and test scope follow the current UK brochure.
Frequently asked questions
Is Blauberg RENEO-120 a single MVHR model?
Yes. RENEO-120 is one simple product with the exact SKU RENEO-120. It uses the RENEO (S71) controller and does not have separate S or SE variants.
Where can the RENEO-120 MVHR unit be installed?
RENEO-120 is designed for ceiling mounting only. Its casing is 242 mm high, 530 mm long and 520 mm wide, with additional space required for the cover, filters, duct connections, condensate drain, electrical connections and future maintenance.
What does the RENEO-120 maximum airflow of 43 l/s mean?
The 43 l/s figure is the catalogue maximum, not the guaranteed airflow at every system pressure. Final selection must use the room-by-room ventilation duty and the resistance of the complete duct system at the intended commissioned operating point.
How efficient is the RENEO-120 heat recovery system?
Catalogue heat recovery is up to 94%. The separate supplied BRE calculation summary reports 83% thermal efficiency, with the duty point not identified in that extract. Keep those figures separate and select the unit using performance data that applies to the required duty.
Does the RENEO-120 include an automatic summer bypass?
No. RENEO-120 does not include a summer bypass. Its compact specification centres on counterflow heat recovery, F7 supply filtration, built-in humidity sensing and connected RENEO (S71) control.
Which replacement filters fit the Blauberg RENEO-120?
RENEO-120 uses an F7 supply filter and a G4 extract filter. The corresponding replacement references are FP-176-150-22-F7 and FP-176-150-22-G4; confirm the current grade and part reference before ordering.
How is the RENEO-120 controlled and connected?
The RENEO (S71) controller provides Blauberg Home Wi-Fi app access, weekly scheduling, boost control, filter reminders, Modbus RTU and operating-data logging. Optional S25 and S22 wired wall controls are also available.
Does the RENEO-120 have a built-in preheater or external-heater control?
No. RENEO-120 does not include a built-in preheater and its RENEO (S71) controller does not provide external-heater control. Account for the stated operating range and the project frost-protection strategy during design.
What ductwork and drainage provisions does RENEO-120 need?
Plan the 100 / 125 mm duct connections, system resistance, acoustic attenuation and trapped condensate drainage before installation. Keep the underside accessible so the cover, F7 and G4 filters, heat exchanger and drain can be inspected and maintained.
What should be checked before specifying a RENEO-120 MVHR system?
Confirm room-by-room supply and extract rates, total airflow, duct resistance, unit location, ceiling access, condensate routing, acoustic treatment, electrical requirements and commissioning access. Correct installation and maintenance also support the five-year UK warranty, subject to its current terms.