Blauberg RENEO-270 MVHR Heat Recovery Ventilation Unit

In stock
Only 100 left
SKU
RENEO-270
£1,738.67 £1,448.89

Blauberg RENEO-270 MVHR

Fresh Air | Heat Recovery | Smart Control

  • Up to 92 l/s airflow for planned residential ventilation.
  • Up to 89% heat recovery to retain useful warmth from outgoing air.
  • Humidity Sensor Built-in with F7 supply filtration as standard.
  • Wi-Fi app control with wall or floor mounting and summer bypass.
  • Connected control S71 control with Wi-Fi app access, operating data logging and Modbus RTU. No preheater included.
  • 5-year warranty UK range cover. Warranty terms apply.
Illustrative contemporary British living space with oak finishes, soft furnishings and a garden view
Blauberg RENEO-270 · whole-home heat recovery

Fresh air.
Home comfort.
All together.

Fresh air. Recovered warmth. Everyday comfort.
Discover whole-home ventilation designed to work beautifully behind the scenes.

Illustrative interior · AI-created
92 l/sMaximum airflow
89%1Catalogue heat recovery, up to
F7Supply filtration as standard
5 yearsUK range warranty · terms apply5-year warranty shield
Original RENEO-270 upright family illustration.
Original RENEO-270 upright family illustration.
Meet RENEO-270

Whole-home
comfort.
Thoughtfully sized.

You put care into every part of a home.
The air inside deserves the same.

RENEO-270 supplies filtered fresh air to living spaces and extracts stale air from wet rooms, recovering useful warmth along the way. A casing just 598 mm wide and 125 mm connections suit a planned cupboard, utility room or plant area.

Humidity Sensor Built-inWi-Fi app controlSummer bypassA SEC class

Select against calculated airflow and system resistance. Maximum airflow is not available at every pressure; final suitability depends on the complete system design.

The everyday difference

Comfort comes
as standard.

Useful warmth retained. Incoming air filtered. Moisture considered. The fundamentals are already part of the specification.

89%1

Keep more
of the warmth.

A counterflow heat exchanger recovers energy from outgoing air, helping reduce the heat lost through ventilation.

F7 supply filter illustrationF7

Fresh air.
Filtered first.

F7 supply filtration is standard, filtering incoming airborne particles before air reaches living spaces.

Humidity Sensor
Built-in.

Humidity sensing helps manage moisture from bathing, cooking and day-to-day life, without specifying an add-on humidity sensor.

1. Up to 89% catalogue heat recovery. Actual performance depends on operating conditions. Independent test results are shown separately below.

Connected to everyday life

Your home.
Your rhythm.

Ventilation that fits the way you live.

Use the Blauberg Home app to plan ventilation around your routine, respond when more airflow is needed and keep track of filter maintenance.

  • Set a weekly schedule. Match operation to the household routine.
  • Boost when needed. Access everyday controls from your phone.
  • Stay informed. Filter reminders and alarm indication help you keep on top of maintenance.
  • Let cooler air be useful. Summer bypass avoids unnecessary heat recovery when conditions allow. It is not active cooling.
RENEO unit with smartphone app and optional wired wall control panels
Wi-Fi app control included. Phone shown for illustration; wired wall panels are optional.
From first sketch to everyday living

Better air.
A shared ambition.

Different priorities. One carefully considered system. Choose your role to see what RENEO-270 brings to your project.

Choose your role to view relevant product benefits

Design with freedom.
Specify with confidence.

Great ventilation belongs in the design conversation early. RENEO-270 combines an upright format with performance data and clear control options. Plan the system around the home and select at the required duty.

Explore the performance data
01

Coordinate the space

900 mm casing height, 125 mm connections and wall or floor mounting.

02

Work from evidence

Compare fan energy use and thermal performance at the required duty. Keep catalogue maxima separate from supplied test results.

03

Plan the integration

S71 provides Wi-Fi app control, Modbus RTU and operating data logging.

From coordinated design
to considered handover.

Choose the control platform, allow for the complete electrical load and plan access from the outset. RENEO-270 has a clear specification to support coordination and handover.

View dimensions & specification
01

Know the electrical requirement

RENEO-270: 182 W maximum total input; 1.4 A maximum total current.

02

Coordinate the installation

Plan 125 mm duct routes, trapped condensate drainage and access to the cover, filters and heat exchanger.

03

Make handover practical

Explain app controls, boost settings and filter reminders. Provide the selected model’s operating and maintenance information.

A clear model.
A stronger conversation.

One clearly defined model makes it easier to match the customer’s project to the right control specification. F7 supply filtration, humidity sensing and Wi-Fi app control are included.

Explore compatible accessories
01

Explain the choice simply

RENEO-270 uses S71 control without an included preheater.

02

Build a complete order

Match the unit with wired wall controls, 125 mm ductwork, condensate drainage and the correct replacement filters.

03

Support the ownership conversation

A 5-year UK range warranty and Blauberg UK project support are useful points to discuss. Warranty terms apply.

A home that feels good.
Day after day.

Enjoy a planned supply of filtered fresh air while recovering warmth from the air leaving your home. RENEO-270 makes ventilation part of everyday living, with controls that fit your routine.

Explore everyday control
01

Keep useful warmth indoors

The counterflow heat exchanger reduces heat lost through ventilation. Catalogue heat recovery is up to 89%, depending on operating conditions.

02

Fresh air, with less to think about

F7 supply filtration and a built-in humidity sensor help manage incoming particles and moisture from everyday activities.

03

Stay in control

Set weekly schedules, use boost when needed and follow filter reminders through the Blauberg Home app. Optional wired panels add control at the wall.

Think beyond installation.
Plan for the life of the home.

A well-considered ventilation specification connects resident comfort, measured performance and ongoing maintenance. RENEO-270 gives project teams clear points to discuss at each stage.

Discuss your project
01

Make performance visible

Use the supplied fan-power and thermal results to inform selection, with the test scope and model applicability kept clear.

02

Support a consistent specification

Use the exact product code, RENEO-270, to keep the agreed control specification clear through design, ordering and handover.

03

Plan for ownership

Accessible filters, clear handover information and a 5-year warranty help frame the maintenance and resident-support discussion.

Make it your specification

Your selected model.

F7 supply filtration, built-in humidity sensing and Wi-Fi app control are included. Here is the exact control specification for RENEO-270.

Connected control

RENEO-270

S71 connected control with operating data logging. A clear starting point for everyday whole-home ventilation.

Controller
S71
Preheater
Not included
Modbus
RTU
Data logging
Yes
External-heater control
No
Max. total power
182 W
Max. total current
1.4 A
Independently tested by BRE

Performance measured.
Confidence earned.

Independent testing puts numbers behind the promise. RENEO-270 reference results measure fan energy use and heat recovery. Use the data at the required duty and keep its scope clear.

SAP 2005 results

Kitchen +
additional wet rooms
Fan speed
setting
Airflow
[l/s]
SFP
[W/(l/s)]
Heat exchange
efficiency [%]
1Supply 28%
Extract 31%
15.00.6490
2Supply 37%
Extract 39%
21.00.6290
3Supply 45%
Extract 47%
27.00.7089
4Supply 52%
Extract 56%
33.00.8789
5Supply 59%
Extract 63%
39.01.0488
6Supply 65%
Extract 69%
45.01.2087

SAP 2012 results

Kitchen +
additional wet rooms
Fan speed
setting
Airflow
[l/s]
SFP
[W/(l/s)]
Heat exchange
efficiency [%]
1Supply 38%
Extract 41%
21.00.6690
2Supply 48%
Extract 51%
29.00.7889
3Supply 56%
Extract 60%
37.00.9488
4Supply 66%
Extract 70%
45.01.2587

Swipe across to see all columns →

Rigid ductwork only. SAP 2005 uses the minimum flow rate condition. The methods are shown separately.

Draft BRE results. Confirm the final report and UK model/F7 filter applicability. Results are not established for every control or preheater variant.

Find your design duty.

Open full-size curve
RENEO-270 airflow in litres per second against static pressure at 30, 70 and 100 percent settings
Use the curve to check the required airflow at the calculated system resistance. Catalogue maximum airflow is not the available duty at every pressure.
Illustrative RENEO installation in a UK loft with rigid insulated EPP ductwork
AI-created installation concept. Confirm ambient conditions, safe access and drainage for the proposed location.
Designed into the home

Quietly working.
Carefully planned.

Give ventilation a considered place in the project: a dedicated cupboard, utility room, plant area or suitable loft location. Wall or floor mounting allows the unit position to follow the design.

Plan the 125 mm duct routes, attenuation, condensate drainage and maintenance access together.

Coordinate your installation
The details that make the design work

Ready for the drawing board.

Dimensions and specifications for RENEO-270. Control and total electrical ratings appear in your selected-model section above.

RENEO-270 dimensional drawing
Dimensions in millimetres. Installation clearances are additional.
Open full-size drawing
Ø D
125 mm
H
900 mm
H1
958 mm
L
452 mm
L1
190 mm
W
598 mm
W1
273 mm
Weight
22 kg

Mounting & maintenance access

Wall or floor mounting. Keep cover, filter and heat-exchanger access clear. Floor supports must provide at least 150 mm for condensate drainage. Confirm port positions and clearances in the model manual.

Maximum airflow
92 l/s
Catalogue heat recovery
Up to 89%
Duct connections
125 mm
Mounting
Wall or floor
Supply filter
F7 standard
Extract filter
G4
Humidity Sensor Built-in
Yes
Summer bypass
Yes
Electrical supply
230 V, 50/60 Hz
Maximum fan power
182 W
SEC class
A
UK arrangement
Left-hand
Casing / insulation
EPP / 45 mm
Heat exchanger
Counterflow polystyrene
Indoor ambient
+1 to +40°C; max. 60% RH, non-condensing
Transported air
−25 to +40°C

Acoustic performance · at 70% airflow

34 dB(A)Sound pressure at 3 m
LpA
55 dB(A)Casing sound power
LwA

LpA uses spherical free-field conditions. Installed room noise depends on operating duty, location and attenuation.

Complete the system

The right finishing touches.

Plan controls, attenuation and drainage alongside the unit. Keep the correct replacement filters on the maintenance schedule.

F7 supply filter illustration

F7 supply filter

FP-356-100-48-F7

Replacement for the standard supply filter.

G4 extract filter illustration

G4 extract filter

FP-356-100-48-G4

Replacement extract filter.

LCD wall control illustration

LCD wall control

S25

Optional wired touch-screen panel.

Wall control illustration

Wall control

S22

Optional wired panel.

CO₂ sensor illustration

CO₂ sensor

CD-3

Optional demand-control sensor.

Duct silencer illustration

Duct silencer

SD-125-600

600 mm long; reduces duct noise.

Condensate trap illustration

Condensate trap

SFK 20x32

Syphon kit for condensate drainage.

Accessory images are illustrative. Confirm the exact model when ordering.

Lifestyle and loft images are illustrative AI-created visuals, not completed project photographs. Original product and accessory images are illustrative. Specifications and test scope follow the current UK brochure.

More Information
EAN Number5056194058070
Control OptionsApp Control
Filter TypeG4 Panel Filter
© 2025 Blauberg UK Ltd. All rights reserved.