Keep the temperature you paid for.
Built-in insulation helps warmed air stay warm and cooled air stay cool between your MVHR or air-conditioning unit and the connected ductwork.
Recent
Clear
Keep warm air warm. Cool air cool. 125mm insulated EPP ventilation ducting in a 1m length for MVHR heat recovery, air conditioning and suitable extract routes.
BlauTHERM
Help the air reach its destination at the temperature you want. This 125mm BlauTHERM duct is supplied in a 1m length, combining built-in thermal insulation with a tough, lightweight wall. Cut to fit with a sharp knife and connect matching push-fit fittings to build your MVHR, air-conditioning or extract route.

Keep conditioned air on course, then make the installation easier to handle, cut and connect.
Built-in insulation helps warmed air stay warm and cooled air stay cool between your MVHR or air-conditioning unit and the connected ductwork.
Insulation helps limit condensation risk along a correctly designed route. Suitable joints and sealing still matter, particularly in lofts and ceiling voids.
Measure, cut and fit the ducting and its insulation as one component.
Lightweight 1m lengths are easier to carry, lift and position in lofts, ceiling voids and plant areas.
Measure the gap and make a square cut with a sharp knife, including the short sections between fittings.
Push clean, matching parts fully home. Add BTG-500 EPP adhesive where extra joint strength and rigidity are required.
A robust expanded polypropylene duct body keeps weight down while retaining the insulation within the wall.
Plan corners, junctions and changes of diameter with matching bends, tees, reducers and beam adaptors. Add supports, silencers or BlauFast connections as required.
Planning a new build, self-build or renovation? Use BlauTHERM on suitable main duct routes between ventilation equipment and the connected system. It is a practical option for planned runs through lofts, ceiling voids and plant areas, with the diameter and layout chosen for your airflow and available space.

Help retain recovered warmth as air travels between your MVHR unit and the connected ductwork. Built-in insulation helps limit unwanted heat loss along the route, including sections passing through cooler spaces.
Carry cooled or warmed air towards the spaces it serves. Insulation helps limit unwanted heat gain or loss along the duct run, supporting the temperature your air-conditioning system is designed to deliver.
Build suitable extract routes for systems removing moisture-laden air from bathrooms, utility rooms and other wet areas. The ventilation system removes the moisture; duct insulation helps limit condensation risk along its route.
This product is the 125mm nominal diameter, supplied in a 1m straight length. Match it to the equipment connections and airflow specified for your installation. Need a different main duct size? The 160mm and 200mm versions are available as separate products below.
This product
1m straight length
BTID-125-1
Separate product
1m straight length
Separate product
1m straight length
Match the diameter to the required airflow and system design, and allow for the outside dimensions of the insulated duct when planning the available space.
Bring the lengths to the job, make the cuts you need and connect the route using matching fittings. The lightweight format is useful when lifting into position and working in the space available.

Measure the actual gap and cut square with a sharp knife. Adjust each straight section on site to suit the space between your fittings.
Plan a matching connector at each 1m duct joint. Keep the surfaces clean and push matching components fully together.
Use BTG-500 EPP adhesive where additional strength and rigidity are required, following its application and curing instructions.
Support the completed route, keep service items accessible, and measure and balance the system to its design airflow.
Use these product details alongside the route design, equipment requirements and current fitting instructions.
This is a 1m straight length of 125mm nominal diameter insulated EPP ducting. The firm, lightweight duct body can be cut to suit the actual space between your fittings.
Check the connection size specified for the unit and the diameter required by the ventilation design. Allow for the outside dimensions of the insulated duct and its fittings when checking the available space.
Yes. Measure the required section and cut the duct square with a sharp knife. Check the joint engagement against the fitting instructions, clean the cut ends and use matching components to complete the connection.
Choose the 125mm connections required for your route, such as couplers, 45° or 90° bends, equal tees and suitable supports. Where the design changes diameter, check both ends of the selected reducer before ordering.
The built-in EPP insulation helps limit heat loss from warmed air along the route, including sections through cooler spaces. Check whether your installation requires additional insulation or vapour sealing, and allow access to items that need servicing.
Matching push-fit joints are designed for airtight connections when correctly assembled. Use BTG-500 EPP adhesive where extra joint strength and rigidity are required, following its application and curing instructions.
Plan suitable supports for the completed duct route and its joints. Check their positions alongside the outside dimensions of the fittings and the space available. Follow the installation instructions rather than relying on the connections alone to support the run.
Use the separate 160mm listing if that is the diameter specified for the route. This page is for the 125mm option. Confirm the required size before ordering the straight lengths and matching fittings.
| EAN Number | 5056194058476 |
|---|