BlauTHERM 160mm Insulated MVHR Heat Recovery Ventilation Ducting - 1m

This product will be in stock soon.
SKU
BTID-160-1
£23.36 £19.47
Selected SKU: BTID-160-1
Availability: Loading...

Keep warm air warm. Cool air cool. 160mm insulated EPP ventilation ducting in a 1m length for MVHR heat recovery, air conditioning and suitable extract routes.

  • Protect your air temperature: Built-in EPP insulation helps keep warmed air warm and cooled air cool along the route.
  • Look after concealed ductwork: Help limit condensation risk on a correctly designed and sealed installation.
  • Make overhead work easier: Lightweight 1m lengths are manageable to carry, lift and position.
  • Fit the space you have: Cut square with a sharp knife, then join with matching push-fit fittings.
  • Complete your 160mm route: Plan matching fittings for bends, junctions and connections to the rest of your system.

BlauTHERM

Keep warm air warm.
Cool air cool.

Help the air reach its destination at the temperature you want. This 160mm BlauTHERM duct is supplied in a 1m length, combining built-in thermal insulation with a tough, lightweight wall. Cut to fit with a sharp knife and connect matching push-fit fittings to build your MVHR, air-conditioning or extract route.

Length
1m
Duct diameter
160mm
BlauTHERM insulated EPP straight duct with matching connector

More comfort in use.
Less hassle on site.

Keep conditioned air on course, then make the installation easier to handle, cut and connect.

Keep the temperature you paid for.

Built-in insulation helps warmed air stay warm and cooled air stay cool between your MVHR or air-conditioning unit and the connected ductwork.

Help protect concealed ductwork.

Insulation helps limit condensation risk along a correctly designed route. Suitable joints and sealing still matter, particularly in lofts and ceiling voids.

Insulation built in

Measure, cut and fit the ducting and its insulation as one component.

Less awkward overhead

Lightweight 1m lengths are easier to carry, lift and position in lofts, ceiling voids and plant areas.

Cut the length you need

Measure the gap and make a square cut with a sharp knife, including the short sections between fittings.

Push-fit connections

Push clean, matching parts fully home. Add BTG-500 EPP adhesive where extra joint strength and rigidity are required.

Tough, lightweight EPP

A robust expanded polypropylene duct body keeps weight down while retaining the insulation within the wall.

A range for the route

Plan corners, junctions and changes of diameter with matching bends, tees, reducers and beam adaptors. Add supports, silencers or BlauFast connections as required.

Where will you use BlauTHERM?

Planning a new build, self-build or renovation? Use BlauTHERM on suitable main duct routes between ventilation equipment and the connected system. It is a practical option for planned runs through lofts, ceiling voids and plant areas, with the diameter and layout chosen for your airflow and available space.

Installed BlauTHERM insulated ductwork with matching joints and supports
BlauTHERM ductwork, matching joints and supports in an installation.

MVHR heat recovery

Help retain recovered warmth as air travels between your MVHR unit and the connected ductwork. Built-in insulation helps limit unwanted heat loss along the route, including sections passing through cooler spaces.

Air conditioning

Carry cooled or warmed air towards the spaces it serves. Insulation helps limit unwanted heat gain or loss along the duct run, supporting the temperature your air-conditioning system is designed to deliver.

MEV and moisture extraction

Build suitable extract routes for systems removing moisture-laden air from bathrooms, utility rooms and other wet areas. The ventilation system removes the moisture; duct insulation helps limit condensation risk along its route.

160mm ducting for your installation.

This product is the 160mm nominal diameter, supplied in a 1m straight length. Match it to the equipment connections and airflow specified for your installation. Need a different main duct size? The 125mm and 200mm versions are available as separate products below.

160 mm

This product
1m straight length

BTID-160-1

Match the diameter to the required airflow and system design, and allow for the outside dimensions of the insulated duct when planning the available space.

Fit the ducting around your installation.

Bring the lengths to the job, make the cuts you need and connect the route using matching fittings. The lightweight format is useful when lifting into position and working in the space available.

Cutting BlauTHERM EPP ducting to length with a sharp knife
  1. Cut to fit.

    Measure the actual gap and cut square with a sharp knife. Adjust each straight section on site to suit the space between your fittings.

  2. Connect the lengths.

    Plan a matching connector at each 1m duct joint. Keep the surfaces clean and push matching components fully together.

  3. Add joint strength.

    Use BTG-500 EPP adhesive where additional strength and rigidity are required, following its application and curing instructions.

  4. Support and commission.

    Support the completed route, keep service items accessible, and measure and balance the system to its design airflow.

The detail behind the ducting.

Use these product details alongside the route design, equipment requirements and current fitting instructions.

Duct diameter
160mm
Length
1000mm / 1m
Material
Expanded polypropylene (EPP)
Operating temperature
-15°C to +60°C
Thermal conductivity
0.03 W/(m·K)
Thermal resistance
0.666 m²K/W
Connections
Matching push-fit BlauTHERM components

Choose with confidence. Fit with a plan.

How long is the 160mm straight duct?

BTID-160-1 is supplied as a 1m straight length in 160mm nominal diameter. Its EPP wall provides the insulation, so the ducting and thermal insulation are handled as one component.

What should I measure before routing 160mm duct through a ceiling void?

Check the outside dimensions of the insulated duct, couplers and bends against the space available. Include the support positions and access needed to assemble and maintain the route before the ceiling is closed.

Can I use 160mm duct on the main connections to an MVHR unit?

Use it where the unit connections and ventilation design specify a compatible 160mm route. Built-in insulation helps limit unwanted temperature change between the equipment and connected ductwork. Choose the complete route against the required airflow and layout.

How do I finish a 160mm run that is not an exact number of metres?

Cut the final section to the required length with a sharp knife, keeping the end square. Check the space needed for the joints, clean the surfaces and reconnect using matching 160mm components.

How do I keep the insulation continuous at 160mm joints?

Use a matching connector at each 1m duct joint and push the components fully together. Support the finished run and maintain any vapour sealing required by the design. Add BTG-500 EPP adhesive where extra joint strength is needed.

Can I connect a 160mm duct route to a 125mm connection?

A matching 160mm-to-125mm reducer provides that size transition where the system design calls for it. Check both connection sizes and the airflow requirements of the complete route before selecting the reducer.

Is the 160mm length practical to handle overhead?

The lightweight EPP construction and 1m format make carrying and positioning the duct more manageable in planned ceiling-void, loft and plant-area routes. Check the available working space and arrange suitable support for the completed installation.

Does the 160mm insulated duct replace an acoustic silencer?

The duct wall provides built-in thermal insulation. Where the ventilation design calls for dedicated acoustic treatment, choose a matching inline silencer as part of the route. Do not select the straight duct as a substitute for a specified silencer.

More Information
EAN Number5056194058483
© 2025 Blauberg UK Ltd. All rights reserved.