A 160mm nominal EPP coupler for joining BlauTHERM insulated ventilation ducting and fittings, including sections cut to suit the installation.
BlauTHERM
Bring your 160mm duct sections together with a matching insulated EPP coupler. Use it where your measured route needs a same-size connection, including ducting cut on site, while keeping the joint within the BlauTHERM insulated system.

Connect the sections your installation needs, with the joint kept inside one matching insulated system.
The EPP coupler continues the matching insulated ducting system through the connection. Fully seated joints and the sealing required by the design help you complete the air path with care.
Measured routes need more than whole metres. A matching coupler helps reconnect duct sections cut to fit the space, so you can plan the actual lengths needed around the installation.
Choose the 125mm, 160mm or 200mm coupler specified for the adjoining ductwork.
Align clean, matching components and push the connection fully home.
The expanded polypropylene body keeps the joint within the insulated duct system.
Lightweight EPP is practical to carry and position along a planned route.
Add BTG-500 EPP adhesive where additional joint strength and rigidity are required.
Coordinate couplers with matching straight duct, bends, tees, reducers and supports.
Plan the couplers alongside the route and equipment, with the nominal size and available space checked before assembly.

Connect the insulated sections between compatible equipment and the connected ductwork. Match the diameter and layout to the ventilation design.
Keep matching insulated components together on suitable conditioned-air routes. The coupler forms the connection within the insulated system.
Join the matching sections needed for a suitable extract route, with clean, fully seated connections and support for the finished installation.
This listing is for the 160mm nominal size coupler. Match both adjoining BlauTHERM components to this diameter. The other sizes below are separate products for different routes.
Separate product
Insulated EPP coupler
This product
Insulated EPP coupler
BTIDC-160
Separate product
Insulated EPP coupler
Allow for the outside dimensions of the insulated duct, joints and fittings when planning the available space.
Prepare the matching components, complete the joint and support the finished route. Check the fitting instructions for your chosen connection arrangement.

Confirm the nominal diameter at both sides of the joint. A straight coupler joins matching sizes; select a suitable reducer for a designed change of diameter.
Keep cut ends square and mating surfaces clean. Check the required engagement against the fitting instructions before finalising a cut section.
Align the matching components and push them fully together. Maintain the insulation and any vapour sealing required by the installation design.
Use BTG-500 EPP adhesive where added strength and rigidity are required, following its application and curing instructions. Provide suitable support for the completed ductwork.
Use these product details alongside the route design and fitting instructions.
It is the nominal duct size used to select matching BlauTHERM connections. Check the outside dimensions of the insulated components as well when planning the space around the joint.
Its expanded polypropylene body forms part of the matching insulated ducting system. Fully seat the connections and keep any insulation and vapour sealing required by the design continuous through the assembled joint.
Yes. Use the matching coupler where a cut section needs reconnecting to the route. Check the finished length and connection engagement, and prepare square, clean duct ends before assembly.
Plan a matching connector at each 1m duct joint in a 160mm run. Count any additional joints around cut sections and check which connectors are already included in your planned components before ordering extras.
Allow space for the outside dimensions of the insulated joint, the assembly and the support positions. Check access to any equipment or fittings that need servicing before the ceiling is closed.
This straight coupler is for matching 160mm components. Use a suitable 160mm-to-125mm reducer where the ventilation design calls for a change of diameter, checking both connections before assembly.
Use BTG-500 EPP adhesive where extra joint strength and rigidity are required, following the application and curing instructions. Continue to provide suitable support for the completed run.
Recheck the nominal sizes, alignment and cleanliness of the mating surfaces. Confirm the intended connection arrangement against the fitting instructions before continuing the assembly.
| EAN Number | 5056194058513 |
|---|