A 200mm nominal EPP coupler for joining BlauTHERM insulated ventilation ducting and fittings, including sections cut to suit the installation.
BlauTHERM
Finish the connections on your 200mm main duct route with a matching EPP coupler. Plan the joints between lengths and cut sections, then build a supported installation with the insulation continued through the matching BlauTHERM components.

Connect the sections your installation needs, with the joint kept inside one matching insulated system.
The EPP coupler continues the matching insulated ducting system through the connection. Fully seated joints and the sealing required by the design help you complete the air path with care.
Measured routes need more than whole metres. A matching coupler helps reconnect duct sections cut to fit the space, so you can plan the actual lengths needed around the installation.
Choose the 125mm, 160mm or 200mm coupler specified for the adjoining ductwork.
Align clean, matching components and push the connection fully home.
The expanded polypropylene body keeps the joint within the insulated duct system.
Lightweight EPP is practical to carry and position along a planned route.
Add BTG-500 EPP adhesive where additional joint strength and rigidity are required.
Coordinate couplers with matching straight duct, bends, tees, reducers and supports.
Plan the couplers alongside the route and equipment, with the nominal size and available space checked before assembly.

Connect the insulated sections between compatible equipment and the connected ductwork. Match the diameter and layout to the ventilation design.
Keep matching insulated components together on suitable conditioned-air routes. The coupler forms the connection within the insulated system.
Join the matching sections needed for a suitable extract route, with clean, fully seated connections and support for the finished installation.
This listing is for the 200mm nominal size coupler. Match both adjoining BlauTHERM components to this diameter. The other sizes below are separate products for different routes.
Separate product
Insulated EPP coupler
Separate product
Insulated EPP coupler
This product
Insulated EPP coupler
BTIDC-200
Allow for the outside dimensions of the insulated duct, joints and fittings when planning the available space.
Prepare the matching components, complete the joint and support the finished route. Check the fitting instructions for your chosen connection arrangement.

Confirm the nominal diameter at both sides of the joint. A straight coupler joins matching sizes; select a suitable reducer for a designed change of diameter.
Keep cut ends square and mating surfaces clean. Check the required engagement against the fitting instructions before finalising a cut section.
Align the matching components and push them fully together. Maintain the insulation and any vapour sealing required by the installation design.
Use BTG-500 EPP adhesive where added strength and rigidity are required, following its application and curing instructions. Provide suitable support for the completed ductwork.
Use these product details alongside the route design and fitting instructions.
Choose BTIDC-200 for a same-size joint between matching 200mm nominal BlauTHERM components. Confirm the diameter at both ends of the proposed joint against the route design.
Use matching connectors at the 1m duct joints and any additional connections needed around cut sections. Plan the complete route, fully seat the joints and provide suitable supports.
It is a same-size joining component. For a planned transition to another diameter, select a matching reducer with both connection sizes checked against the design.
Check the outside dimensions of the actual insulated duct and joint, together with assembly space and support positions. Nominal duct size alone does not describe the full space needed in a ceiling void or plant area.
The coupler is intended for matching BlauTHERM components. Check the equipment connection and the required fitting arrangement before assembly rather than assuming every nominal 200mm spigot uses the same connection.
Measure the required section, make a square cut with a sharp knife and clean the mating surfaces. Check the required joint engagement and fully seat the matching components before supporting the run.
Matching push-fit joints are designed for airtight connections when correctly assembled. Use BTG-500 EPP adhesive where extra joint strength and rigidity are required, following its instructions.
The EPP coupler forms part of the insulated ducting system. Keep the joint fully assembled and maintain the insulation and any vapour sealing required by the installation design.
| EAN Number | 5056194058520 |
|---|